Fanuc turret alarm

This program makes sure the turret lock sensor operates correctly. This program makes sure the turret unlock sensor operates correctly:.

Contact Us

Turret Unl. To make this site work properly, we sometimes place small data files called cookies on your device. Most big websites do this too. A cookie is a small text file that a website saves on your computer or mobile device when you visit the site. View Privacy and Cookie Notice. This price includes shipping cost, export and import duties, insurance, and any other expenses incurred during shipping to a location in France agreed with you as a buyer.

Sign up now! Web Pages. Alarm Quick Search. No matching alarm was found for the given alarm code. Loading Tools? Always Do This First. Water in Your Air System? Check This Out! Haas Factory Update.

Doosan TT Series Alarms

Indexable Cutting Tools Coming Soon! Indexable Inserts Coming Soon! Carbide Cutting Tools Coming Soon! Contact Us. My Cart. Find A Dealer. Introduction 2. Machine Compatibility 3. Lathe - Turret Lock Sensors - Adjustment 2 steps 4. This procedure tells you how to adjust the turret locked and unlocked sensors.

The procedure shows a ST with software version L Machine Compatibility. Lathe - Turret Lock Sensors - Adjustment. Do these steps. Slowly move the lock sensor and clamp up. Put a mark on the turret lock cylinder on the outside of the lock sensor clamp. Move the lock sensor and clamp to the middle point between the two marks.

Tighten the clamp. T1; G04 P1. Lathe - Turret Unlock Sensors - Adjustment. Loosen the unlock sensor clamp. Slowly move the unlock sensor and clamp up. Put a mark on the turret lock cylinder on the outside of the unlock sensor clamp.Please contact us if you need testing, a repair or an exchange part. Note: Alarm in background edit is displayed in the key input line of the background edit screen instead of the ordinary alarm screen and is resettable by any of the MDI key operation.

PSM: Control power voltage has dropped. SVM: the motor current is too high. PSMR: The regenerative amount is too large. PSM: The internal stirring fan failed. PSMR: The external dissipator stirring fan failed. Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information. Or input of two decimals.

The alarm is generated also when a G code with which the control is not equipped as an option is commanded. In canned cycle mode, an ATC cycle M06 is commanded. Push the reset button after turning off the switch. Error on Stroke Limit Switch The movable part of machine touched the X Axis plus stroke limit switch The movable part of machine touched the X Axis minus stroke limit switch While the X Axis was moving in the plus direction, It entered into the forbidden area of the stored stroke limit 1 While the X Axis was moving in the minus direction, It entered into the forbidden area of the stored stroke limit 1 While the X Axis was moving in the plus direction, It entered into the forbidden area of the stored stroke limit 2 While the X Axis was moving in the minus direction, It entered into the forbidden area of the stored stroke limit 2 The movable part of the machine touched the Y axis plus stroke limit switch The movable part of the machine touched the Y axis minus stroke limit switch.

Perform manual reference point return again The content of error register of the X axis is larger than the value allowed while the machine is stopped The content of error register of the Y axis is larger than the value allowed while the machine is moving Drift in X axis is excessive.

An incorrect setting of CMR causes this error X axis pulse coder position feedback is abnormal. Disconnection alarm The content of the error register of the Y axis is larger than the value allowed while the machine is stopped The content of the error register of the Y axis is larger than the value allowed while the machine is moving Drift in Y axis is excessive.

fanuc turret alarm

An incorrect setting of CMR causes this error Y axis Fanuc pulse coder position feedback is abnormal. Disconnection alarm The content of the error register of the Z axis is larger than the value allowed while the machine is stopped The content of the error register of the Z axis is larger than the value allowed while the machine is moving Drift in Z axis is excessive.

An incorrect setting of CMR causes this error Z axis pulse coder position feedback is abnormal. Disconnection alarm The content of the error register of the 4 TH axis is larger than the value allowed while the machine is stopped The content of the error register of the 4 TH axis is larger than the value allowed while the machine is moving Drift in 4 TH axis is excessive. Also in another case change connection unit PC program has not yet been loaded The correspondence between NC and PC is incorrect or interrupted.

Errors on memory Fault in bubble device. Fault of input signal for bubble device Fault in bubble device. Page size error, undefined command Fault in bubble device. Transfer missing, page size over Fault in Fanuc bubble device. Parity error Fault in bubble device. No marker Fault in bubble device. Note Note: Alarm in background edit is displayed in the key input line of the background edit screen instead of the ordinary alarm screen and is resettable by any of the MDI key operation.

Failure in data transmission. In simple synchronous control, the compensation amount for the synchronization exceeds the value set in parameter No This error occurs as the result of improperly set CMR. A proper value 0r is not set in parameter No Illegal data a value below 0, etc was set in parameter No Parameters No and No have not been set.

A torque control parameter is set incorrectly in PMC axis control.Logging in Remember me. Log in. Forgot password or user name? Hardinge conquest 42 turret alarms ot fanuc. Posts Latest Activity. Page of 1. Filtered by:. Previous template Next. Hardinge conquest 42 turret alarms ot fanucPM. I just got all my parameters reloaded on my hardinge conquest cs42 i can home the machine but if its not on tool station 1 I will get a turret unclamped alarm If its on station 1 it'll be fine but if I use the tool selection knob it'll go to the wrong tool and won't clamp into position and will alarm out.

I also noticed when I flip the knob to tool 11 or 12 it won't do anything. Now I changed parameter and like the book said to do for my 12 station turret. But it's still acting like its thinking its possibly a ten station turret.

I tried to enter D Do you have any ideas on how to fix this!!! Is there a parameter I am missing??? Any help would be greatly appreciated!!! Thanks Rick. Tags: None. Re: Hardinge conquest 42 turret alarms ot fanuc Just wondering, but have to tried to re-home the turret? I believe it was e-stop reset and turret index soft keys held down together and the turret clear.Detected that the 3-phase input to the main circuit of the PSM has an open phase.

fanuc turret alarm

Detected that the 3-phase input has an open phase. Overspeed Analog The temperature sensor is abnormal in the motor, or the temperature sensor cable is broken. Overspeed Digital. Temperature of the heat sink of the SPM main circuit has risen to the set value.

Heat sink is overheated. PSM detected that the DC link voltage was excessively high. DC link overvoltage. DC link voltage was excessively high.

Spindle switching operation sequence was not executed correctly. The power to the CNC is turned off. This symptom does not represent an error. Serial communication data transferred between the CNC and spindle amplifier module contains an error. Serial communication between the CNC and spindle amplifier module stopped. Serial transfer data error. An excessive load standard setting: load meter reading of 9 V has been applied continuously for a certain period standard setting: 30 seconds.

An excessively large current is detected at the input of the 3-phase main circuit of the PSM. Defective power regeneration circuit. The PSM could not be charged within a specified time. PSM input has an open phase.

WC-203 Turret index time over

DC link circuit problem. The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type. After emergency stop signal input, the motor is accelerated without being decelerated.

Incorrect parameter setting for the number of speed feedback pulses. The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set. Incorrect data ROM type for Cs contour control detector circuit or incorrect setting. Incorrect setting of parameter of number of position coder signal pulses. Alarm for indicating position coder 1 -rotation signal not detected. The position coder signal of the spindle on the mater side used in the differential speed mode is disconnected.

Alarm for indicating disconnection of position coder signal for differential speed mode. The one-rotation signal of the position coder cannot be detected normally during thread cutting.

Alarm for indicating failure in detecting position coder 1 -rotation signal in thread cutting operation. The pulse count value of the MZ sensor or BZ sensor is abnormal. Incorrect setting of parameter for number of position coder signal pulses. In the differential speed mode, the spindle speed on the master side remote converted to a motor speed on the slave side local exceeded the maximum allowable speed of the motor.

Excessive speed command calculation value in spindle synchronization control.Below is a list of FANUC servo amplifier alarms and faults with a short description briefly describing the source of each error code. Blinking "-". Keep the cable on the Servo Amplifier side connected. Overcurrent flowed into the input of the main circuit. Input supply voltage imbalance, IGBT defective. The main circuit power module IPM has detected an overload, overcurrent, or control supply voltage decrease, overcurrent, or control supply voltage decrease.

Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. Regenerative discharge energy is too high. The input power supply is abnormal open phase or the main circuit capacitor was not recharged within the specified time. When the absolute pulse coder is used, the motor has not yet rotated through more than one turn after the first power—up. When the magnetic contactor is turned on, the phase sequence of the power supply cannot be determined.

No LED. A first to third reference position return cannot be executed because the reference position has not yet been established. The n—th axis axis 1—8 overload signal is on. Refer to diagnostic display No. Position control system fault. Due to an NC or servo system fault in the reference position return, there is the possibility that reference position return could not be executed correctly. Try again from the manual reference position return. Abnormal servo motor load has been detected.

Alternatively, abnormal spindle motor load has been detected in Cs mode. The position deviation value when the n—th axis axis 1—8 stops is larger than the set value. The position deviation value when the n—th axis axis 1—8 moves is larger than the set value.How is it solved? Wonder if anyone is familiar with this error message and knows what causes it!? Any help would be highly appreciated. I have Fanuc 18 m controller vmc machine. Your email address will not be published. This site uses Akismet to reduce spam.

Learn how your comment data is processed. To order a replacement part or a repair job, please call or email sales mroelectric. Correct the tape.

This alarm will be generated only when the TV check is effective. Refer to the item of max. Modify the program. Or two decimal points were input. Offset is not canceled but another axis is offset for the tool length offset type C.

Otherwise, the number specified by P code for the additional workpiece coordinate system is too large. T Series: A point of intersection cannot be determined for tool nose radius compensation. The plane selected by using G17, G18 or G19 is changed in cutter compensation C mode. The program may cause overcutting to occur in chamfering or corner R.

Two or more blocks are consecutively specified in which functions such as the auxiliary function and dwell functions are performed without movement in the cutter compensation mode. Alternatively,Q0 is specified. Correct the program. For systems with this feature, a comma was followed by something other than R or C Correct the program. In the chamfering comman, I K is commanded for the X Z axis. Otherwise, a program specified for searching is being edited in background processing.

Alternatively, the program with the program number specified in a one—touch macro call is not found in memory. Check the program number and external signal. Or discontinue the background editing. Check the sequence number. The depth of cut in G71 or G72 is zero or negative value.

APC Alarms Solution 300 APC Alarm DS030 Need Reference Return

The repetitive count in G73 is zero or negative value. Zero or a negative value is specified to the height of thread or depth of cut of first time in G The specified minimum depth of cut in G76 is greater than the height of thread. An unusable angle of tool tip is specified in G G00 or G01 is not commanded at the block with the sequence number which is specified by address P in G71, G72, or G73 command.Results 1 to 8 of 8. The tool rotates but the turret does not?

Do not understand what you mean about that. If the turret disengages but doesn't move you may have a broken drive belt. Also check to see if the proximity switch for turret unlocked is on and the sw for locked is off when it is disengaged. Originally Posted by spark-el.

FANUC Alarm Codes List

When you rotate unlock a live-tool by hand it causes an alarm. Rotate it till you feel the "lock" and replace it on the turret. Your Electrical Victor manual contains a chapter how to rotate the turret when above solution dosn't work.

Now the turret rotates to the right position. Originally Posted by zavateandu. Sorry, I made a mistake in how to unlock the Sauter-turrets on my Doosan. Attached Thumbnails. Need help! Similar Threads Yaskawa Servopack error: A. Replies: 0 Last Post:AM. Turret in Wrong position By chipsahoy in forum Fanuc.

Replies: 4 Last Post:AM. Replies: 1 Last Post:PM. The time now is AM. All rights reserved. This website uses cookies We use cookies to optimize our website for you and to be able to improve it continuously.

fanuc turret alarm

By clicking the "Agree" button, you expressly agree to the use of cookies. For further information on cookies, please refer to our privacy policy. More infomations about the cookies and further configurations.


Comments

Leave a Comment